- Home
- Services
- EIFS & Dryvit Restoration
EIFS & Dryvit Restoration in Newnan
Much of Newnan’s newer commercial space is clad in EIFS, and the oldest of it is now showing failed joints, impact damage and faded finishes. We repair and restore EIFS and Dryvit facades with materials that belong on them.
- EIFS & Dryvit repair
- Joint & sealant renewal
- Facade recoats
- Drainable conversions
Request a commercial quote
Newnan commercial stucco & EIFS. Property managers, boards, owners & builders.
EIFS needs an EIFS repair
EIFS is a layered system: insulation board fastened or adhered to the sheathing, a base coat with embedded fiberglass mesh, and a thin acrylic finish. It is lighter and more flexible than cement stucco, and it has to be repaired as a system. A cement patch or a smear of caulk on an EIFS facade cracks at its edges and often holds water against the board.
Many of the retail towers, office facades and apartment buildings put up as Newnan grew toward the interstate were clad in EIFS, and some of the earlier ones are barrier systems that rely entirely on the face of the wall and its sealant joints. With no drainage behind them, a failed joint at a window or a missing flashing at the roof line sends water straight into the sheathing. Later drainable systems add a weather barrier and a drainage path.
We identify which system is on the wall, take moisture readings at its weak points and scope the work to match: joint and perimeter sealant replacement, mesh and base coat repairs, sheathing replacement where the board is wet, recoats that refresh the finish, and drainable conversions where the building calls for one.

EIFS & Dryvit restoration in Newnan
Most EIFS problems come down to water at the edges or damage to a soft face. The scope depends on whether the substrate behind is still dry.
Wet substrate repair
Wet sections are cut out, damaged sheathing replaced with glass-mat gypsum board, and the wall rebuilt with new board, mesh, base coat and finish.
Joint & sealant renewal
Failed sealant at windows, storefronts and panel joints is replaced with backer rod and an EIFS-compatible sealant against a sound edge.
Facade recoats
A new finish coat over sound EIFS renews color and texture across an entire elevation or building without removing the system.
Barrier to drainable conversion
Failing barrier EIFS is removed and replaced with a drainable system over a weather barrier, elevation by elevation if needed.
Impact damage
Dents and punctures at entrances, loading areas and ground-floor corners are cut back, rebuilt with heavier mesh where needed and blended in.
Below-grade foam & termites
Foam board run into soil or under pavement gives termites a hidden path. We cut it back above grade and repair damaged framing.
Choosing the right EIFS scope
If moisture readings are low and damage is local, section repairs with new sealant joints and a matched finish are usually the right answer. If the facade has been patched many times or faded unevenly, a recoat across the elevation gives a uniform look and helps a dated building show better to tenants and prospects.
When barrier EIFS shows wet readings in many places, repairing spot by spot often just moves the problem. Converting to a drainable system, or to hard coat stucco or fiber cement on some elevations, can be the better long-term choice. We explain the options with readings and photos in front of you, separate urgent work from what can be phased, and document any change in scope for your approval before we proceed.
| Scope | Best for | Result |
|---|---|---|
| Section repair | Local damage, dry substrate | Blended to corners |
| Joint renewal | Failed sealant, sound wall | Edges closed |
| Facade recoat | Patched or faded elevations | Uniform building |
| Drainable conversion | Widespread wet barrier EIFS | New drainable system |
How an EIFS restoration runs
Restorations run elevation by elevation, so tenants and residents keep their entrances, parking and daily routine.
Identify & survey
We confirm whether the facade is barrier or drainable EIFS and take moisture readings to find the edges of any wet area on each elevation.
- System identified
- Readings mapped by elevation
- Photo documentation
Remove & rebuild
Damaged EIFS and wet sheathing come out. New sheathing, weather barrier and insulation board go in, with flashing corrected at the leak.
- Wet sheathing replaced
- Flashing corrected
- Foam kept above grade
Mesh, coat & finish
Base coat and reinforcing mesh are lapped into the existing wall, joints are sealed, and the finish is matched or the elevation recoated.
- Mesh lapped into old work
- Compatible materials
- Matched finish
Not sure if the building is EIFS or stucco?
EIFS sounds hollow and feels softer than cement stucco when tapped. We confirm it on the first site walk.
Where Newnan EIFS needs attention
EIFS ages in the same order on most buildings: joints first, then the finish, then whatever is behind any joint that was left open.
EIFS shaped into towers, cornices, bands and accent profiles is common on retail centers and restaurants near the interstate interchanges, and on many office and multifamily buildings across Newnan. Those foam shapes and their flat tops are where we find cracked finish and open seams most often. Georgia hail and summer storms add impact damage and wet joints to the list.
Barrier-era facades
Older EIFS with no drainage, where every joint failure goes straight to the sheathing and needs a moisture survey.
Towers & profiles
Foam cornices, bands and parapet trim with flat tops that hold water and crack the finish.
Hail & impact
Punctures and dents in the soft finish that open the board to water if left unrepaired.
- Newnan
- Bullsboro Drive
- Ashley Park
- Thomas Crossroads
- Downtown Newnan
- Sharpsburg
- Peachtree City
- Senoia
- Moreland
- Grantville
EIFS & Dryvit repair FAQ for Newnan
Answers for Newnan owners and managers with EIFS on their buildings.
Do you repair Dryvit on Newnan commercial buildings?
Does an EIFS restoration in Newnan need a permit?
How do I know if our EIFS is barrier or drainable?
Can EIFS be recoated instead of replaced?
Can we change the color of our EIFS building?
Request an EIFS restoration quote in Newnan
Tell us about the building and what you are seeing. We will survey the EIFS and send a written, itemized scope.